MedCaT B.V., Medische Apparatuur en Toebehoren

[contact] - [informatie aanvraag] - [Mailing list]

HiDop®300  Product specification 
HiDop®PC     Software
2MHz CW probes
obstetric application / air emboli detection
4MHz CW probe
deep vessel applications
8MHz CW probe
peripheral vascular applications
 
Applications:
deep vessel
peripheral vascular
air emboli detection
obstetric

Thermal printer
112 mm paper width
high speed grafic print out

 

Product Specification      HiDop® 300

Doppler

CW 2MHz, 4MHz and CW 8MHz, vascular bidirectional
CW 2MHz, fetal unidirectional

Probes

CW 2MHz, flat probe for air emboli detection during surgery
CW 2MHz, for obstetric applications
CW 4MHz, for deep vessel applications
CW 8MHz, for peripheral vascular applications
Other probes / frequencies upon request
All probes with integrated Doppler electronics

Probe identification

Automatic with digital code

Signal Processing

Real time FFT (Fast Fourier Transform),
256 points overlapping, 6.4 ms
ACF (Auto-Correlation-Function) for fetal heart rate detection

Waveforms

Sonogram
F MAX/MIN
F MAX+MIN
Trend of heart rate (for 2MHz probes only)

Calculations / Indices

Heart Rate (HR), Mean Velocity (Mean),
Pourcelots Resistance Index (RI), Pulsatility Index (PI),
Systolic over Diastolic Ratio (S/D)

Display

160 x 150 pixels, black / white LCD graphic display

Replay Buffer Size

4 displays

Frequency Ranges

+/- 2.5kHz, +/- 5kHz, +/- 10kHz

Wall Thump Filters

100Hz, 200Hz, 400Hz

Display Time

2s, 4s, 8s
60s, 120s, 240s for trend of heart rate

Controls

6 button control of all parameters

Memory for setups

Memory for user setups

Data Memory (Option)

Memory for up to 100 sets of sonograms, up to 64 Mbyte

Indications

Probe Identification, Displayed Waveform, Symbol for Heart Rate
Wall Thump Filter, Frequency Range, Flow Direction

Audio

500mW speaker (mono), output for stereo headphones

Recorder

Output for analog recorder

Data Interface

115kbaud serial interface (standard RS232)
to personal computer for on-line / off-line data transfer
Serial interface to thermal printer

Power

Alkaline batteries, 4 x 1.5V AM3/LR6

 

or 7.5V DC power supply

Battery Life

Min. 6 hours of operation
Display of Low Battery symbol

Automatic Power Shut Off

3 minutes without signal

Size

17.5cm x 11cm x 5cm

Weight

500 grams (Including batteries and 1 probe)

Size of probes

14mm x 110mm (0 x L), CW 4MHz and CW 8MHz
33mm x 8mm (0 x L), CW 2MHz flat probe
33mm x 14mm x 120mm (0 x L), CW 2MHz fetal

 

Specifications are subject to change without notice

 

 

 

MedCaT B.V., Kerklaan 15, NL-7887 AT  ERICA, NEDERLAND, Tel: 0591-301033, Fax: 084-8300 942, info@medcat.nl
Registratie Kamer van Koophandel/Chambre of Commerce: 04061236 in Meppel

MedCaT BVBA, Middelmolenlaan 175, B-2100  Deurne, Belgie, Tel: 03-327 3854, Fax: 03-324 3336 info@medcat.be
RPR Antwerpen: 889 559581

MedCaT GmbH, Fürstenriederstr. 297a, D-81377 München, Deutschland, Tel: 089-74120 280, Fax: 089-74120 102, info@medcat.de

Laatste verandering op deze paginga: 04-07-2008
© MedCaT B.V., 2008
Vragen of opmerkingen n.a.v. deze website sturen aan: website@medcat.nl